View More Info S E G Instrument W10 0 SEG 140a SEG 141 Mass Flow Meter Danfoss Massflo 6000 Manual argelatobasket com Chevy Express 2010 Manual Download Kullervonkatu 20 B 112 33500 Tampere Finland 358 10 292 2090 Office hours Monday – Friday 9 00 – 17 00 Follow us on Facebook Local time 08 32 45 am. View and Download Danfoss PFM 1000 user manual online. Balancing Measuring Device. For Mobile Devices with iOS. PFM 1000 Measuring Instruments pdf manual download. We offer a wide range of products that meet the growing need for infrastructure, food supply, energy efficiency and climate-friendly solutions.
Basic Elements
Contents 1 Introduction 4 1.1 Software Version 4 1.2 Approvals 4 1.3 Definitions 4 1.3.1 Frequency Converter 4 1.3.2 Input 4 1.3.3 Motor 4 1.3.
Just like other flowmeters, differential pressure flowmeters consist of two elements. They are:
A primary element: This element causes a change in kinetic energy which results in the differential pressure in the pipe. The unit must be suitably matched to the
- pipe size,
- flow conditions, and
- the liquid’s properties
Besides, the measurement accuracy of the element must be fine over a practical range.
A secondary element: The secondary element measures the differential pressure created by primary element and gives the signal or read-out which is in turn transformed to the actual flow value.
Types of Differential Pressure Flowmeters
Danfoss Flow Meter User Manual Diagram
Most widely used differential pressure flowmeters are:
- Orifice Plates
- Flow Nozzles
- Venturi Tubes
- Variable Area flowmeters, i.e. Rotameters
Accuracy & Rangeability
Performance of a head-type flowmeter installation is a function of the
- precision of the flow element and
- the accuracy of the d/p cell
On average, flow element precision is expressed in percentage of actual reading terms, whereas d/p cell accuracy is stated as a percentage of calibrated span. A d/p cell typically provides accuracy of ±0.2% of the calibrated span. With no detrimental effect on accuracy, rangeability of a flowmeter can be extra enhanced by employing several d/p flowmeters in parallel runs.
Errors and Noise
In case of compressible fluids, the ratio of differential pressure divided by upstream pressure should not exceed 0.25 for reduction of error and correction of density. Metering errors caused due to wrong installation of the primary element can become considerable i.e. up to 10%. Following are the possible causes of these errors:
- the condition of the mating pipe sections
- insufficient straight pipe runs
- pressure tap and lead line design errors
In turbulent flow conditions, not more than 10% of the d/p signal could possibly be noise produced by disturbances from valves and fittings. These disturbances can be both up- and downstream of the element, and by the element itself. To sort out this noise, a damping is provided in d/p cells which prove to be adequate for majority of the applications. Rigorous noise can be diminished by applying two or more pressure taps connected in parallel on both sides of the d/p cell.
Sources
OmegaTech
Danfoss Flow Meter User Manual Free
Engineering Toolbox
Omega.literature
Here you will find our documentation such as data sheets and operating manuals for our measuring instruments. If you do not find the document, approval or certificate you are looking for, please contact us, we look forward to hearing from you (info@metra-emt.de)!
Your team from METRA Energie-Messtechnik GmbH
Brochures
Product data sheets
Measurement system “oriflow” with compact orifice |
Measurement system “autarkon” with compact orifice – EWZ 120.1 & EWZ 127.1 |
Measurement system “autarkon” with standardized differential pressure devices – EWZ 140.1/147.1 |
Measurement system “autarkon” with venturi tube 150.1/157.1 Steam / Gas |
Measurement system “autarkon” with venturi tube – 150.1/157.1 Liquids |
Measurement system “autarkon” with cross probe – EWZ 211.7 |
Measurement System “autarkon” with cross probe – EWZ 311.7 |
Ultra sonic meter for heat / cooling applications – EWZ 817 |
Ultra sonic meter for heat / cooling applications – EWZ 817G |
Ultra sonic meter for heat / cooling applications – EWZ 817T |
Ultra sonic meter for heat / cooling applications – EWZ 837 |
Magnetic inductive meters for cooling applications – EWZ 617 |
Magnetic inductive meters for cooling applications – EWZ 617 calibrated |
Vortex Meter – VTX3 |
Flow and Energy Calculator – ERW 700 |
Temperature sensor |
Danfoss Flow Meter User Manual Instructions
Operating Manuals
Measurement system “oriflow” with compact orifice |
Measurement system “autarkon” with compact orifice – EWZ 120.1 & EWZ 127.1 |
Measurement system “autarkon” with standardized differential pressure divices – EWZ 140.1/147.1 |
Flow and energy calculator ERW 700 |
Flow and energy calculator ERW 700, “M-Bus Extension” |
Flow and energy calculator ERW 700, “Profibus Extension” |
Flow and energy calculator ERW 700, “RS 485 Extension” |
Flow and energy calculator ERW 700A |
Flow and energy calculator ERW 700(A) “Modbus Extension” |
Measurement system “autarkon” with cross probe – EWZ 211.7 |
Measurement system “autarkon” with cross probe – EWZ 311.7 |
Ultra sonic meter for heat / cooling applications EWZ 817 / EWZ 837 |
Magnetic inductive meters for cooling applications – EWZ 617 |
Vortex Meter – VTX3 |
Vortex Mester VTX3 additional Manual Ex-protection |
Temperature sensor |
APPLICATION EXAMPLE
Steam Measurement by mean of a ISA 1932 Nozzle |
Standard volume flow measurement Venturi tube |
MID
Messsystem “autarkon” mit Kreuzsonde |
Durchfluss- und Energierechner – Wärme |
Durchfluss- und Energierechner – Kälte |
Pressure Equipment Directive
EC Type Examination Certificate Module H Vortex Meter VTX3 |
EC Type Examination Ex- Approvals
EU Type Examination Certificate Vortex Meter VTX3 KIWA 18 ATEX 0041 X |